bando_pac_en.jpg


HPI S 27

Technical characteristics
Heating output: 24.4 kW
COP (T° outside air + 7°C / T° water outlet + 35°C): 3.9
Seasonal energy efficiency heating: 113%
Outside sound level: 75 dB
Inside sound level: 43.4 dB
Equivalent CO₂: 16.08 t
Refrigerant fluid: R410 A
Outdoor air operating range: -20°C/+35°C
Power supply: three phase

Functions
Electrical backup up to 9 kW (single-phase) / 12 kW (three-phase)
Hydraulic back-up by backup boiler
Refreshing (reversible)
Production of Domestic Hot Water by independent DHW tank type 150 to 500 L or BEPC 300


Regulation unit
Diematic Evolution
Compatible with the connected room thermostat Smart TC° and its APP

Dimensions and weight
Indoor unit
Height (mm): 900
Width (mm): 600
Depth (mm): 498
Weight (empty) (kg): 72

Outdoor unit
Height (mm): 1338
Width (mm): 1050
Depth (mm): 417
Weight (empty) (kg): 141